Fixed IR Camera

FIXED camera
gasviewer

Home / Products / Leak Detection / Fixed IR Camera
Explosion
Fixed Gas Detection Camera

FIXED CAMERA

OGI FIXED COOLED CAMERA GASVIEWER GV-F-3234

The GasViewer GV-F-3234 is an advanced Optical Gas Imaging (OGI) fixed cooled camera designed for continuous on-site gas leak monitoring. It provides real-time visualization and quantification of gas clouds, enhancing safety and environmental compliance. This comprehensive turnkey solution includes a field junction box, control room hardware, alarms, and seamless integration with the Distributed Control System (DCS). Moreover, it is certified for safe operation in hazardous areas (Atex zones 1 and 2). This OGI camera essentially functions as a highly effective gas detector, ensuring round-the-clock vigilance for potential leaks.
ACCURACY
Capable of detecting as low as 0.3 grams per second (gr/sec) of CH4 at 125 meters or 0.5 gr/sec of CH4 at 250 meters.
ALARMS
  • The system screen in the control room is equipped with automatic visual and audible alarms.
  • Optional features include sending SMS or email notifications to the designated person on call.
  • Integration with your Distributed Control System (DCS) is also available as an option.
CONNECTIVITY
  • Offers flexibility in connectivity options.
  • For camera-to-control room communication: Fiber optic or wireless connections are available as optional choices.
  • For communication between the system server in the control room and your DCS: Modbus or dry contact connections can be used (both optional).
RECORDING
  • Automatic video recording initiates with every alarm and continues for the duration of the alarm event.
  • Based on the specific needs of our customers, additional recording times can be customized, such as 24/7 recording for a certain number of days.
  • Videos are stored on the system’s hard drive, and a user-friendly interface facilitates easy retrieval and playback for later analysis.
SAFETY CERTIFICATIONS
The system is certified with ATEX II 2G Ex db IIC T6 Gb, with an option for zone 1 availability.
SYSTEM FLEXIBILITY
The system server and software have the capability to manage multiple GV-F-3234 units.
DETECTED GASES
The system is designed to detect over 400 different compounds, including but not limited to Methane, Acetic acid, Benzene, Butadiene, Butene, Butane, Dimethyl-Benzene, Ethane, Ethylene, Ethyl benzene, Ethylene oxide, Hexane, Heptane, Isobutylene, Isopropyl alcohol, Isoprene, Methanol, MEK Methyl Ethyl Ketone, Octane, Pentene, Propane, and Propanol.

Model Variations 

GV-F-3234

Fixed Camera

FIXED CAMERA

OGI FIXED UNCOOLED CAMERA GASVIEWER GV-F-714

Likewise, the GasViewer GV-F-714, an uncooled OGI fixed camera, provides identical capabilities for continuous gas leak monitoring around the clock.It enables real-time colorization and quantification of gas clouds, further bolstering safety measures and regulatory adherence. Like its cooled counterpart, this solution encompasses a field junction box, control room hardware, alarms, and seamless DCS integration. It also holds certification for safe operation in hazardous areas (Atex zones 1 and 2). This OGI camera effectively serves as a reliable gas leak detector, delivering continuous surveillance for potential leaks.

ACCURACY
Capable of detecting as low as 0.5 grams per second (gr/sec) of CH4 at 100 meters or 0.3 gr/sec of CH4 at 50 meters.
ALARMS
  • Offers automatic visual and audible alarms on the system screen in the control room.
  • Optional features include sending SMS or email notifications to the designated person on call.
  • Integration with your Distributed Control System (DCS) is also available as an option, should you be interested.
CONNECTIVITY

Allows for flexibility in connectivity options:

  • For camera-to-control room communication: Fiber optic or wireless connections are available as optional choices.
  • For communication between the system server in the control room and your DCS: Modbus or dry contact connections can be used (both optional).
RECORDING
  • Automatic video recording initiates with every alarm and continues for the duration of the alarm event.
  • Additional recording times can be configured based on customer requirements (e.g., 24/7 recording for a specified number of days).
  • Videos are stored on the system’s hard drive, and a user-friendly interface facilitates easy retrieval and playback for later analysis.
SAFETY CERTIFICATIONS
The system is certified with ATEX II 3G Ex ec IIC T4 Gc, with an option for zone 1 availability.
SYSTEM FLEXIBILITY
The system server and software are capable of managing multiple GV-F-714 units.
DETECTED GASES
The system is designed to detect a range of gases including CH4, SO2, VOCs, NH3, SF6, Methanol, and cooling gases (CFC, HCFC), among others.

Model Variations 